1500 kVA Shenton Perkins 4012-46TWG3A Acoustic Diesel Generator – 2024

At a glance
- Power (kVA)
- 1360 prime / 1500 standby
- Engine
- Perkins 4012-46TWG3A V12
- Year
- 2024
- Hours run
- Test Hours Only
- Voltage
- 400 / 230 V
- Phase
- 3
Test Hours Only.
Available. One generator in this listing. Price on enquiry.
Enquire about this generatorSpeak to our team: 01829 863497Download datasheetOverview
- 2024 Shenton PHG1500Pe acoustic diesel generator, available as one unit under stock reference FWC003. Price on application.
- 1360 kVA / 1088 kW prime output and 1500 kVA / 1200 kW standby output.
- Perkins 4012-46TWG3A V12 diesel engine coupled to a Stamford S6L1D-H41 alternator.
- 400 / 230 V, 50 Hz, three phase and 1500 rpm.
- Acoustic, weather-resistant enclosure with an integral 2500-litre fuel tank.
- Test Hours Only.
1500 kVA Perkins diesel generator for sale
FW Power Generators offers this 2024 Shenton PHG1500Pe acoustic diesel generator for demanding commercial, industrial and critical standby power applications.
The Perkins 4012-46TWG3A is a heavy-duty 45.5-litre V12 diesel engine, operating at 1500 rpm with turbocharging, water-cooled aftercooling and electronic governing. It is coupled to a genuine Stamford S6L1D-H41 synchronous alternator.
With 1360 kVA prime and 1500 kVA standby output, the set can support extended operation under varying load or emergency power during a mains failure, subject to the required duty and site specification.
The substantial acoustic enclosure and integral fuel tank provide a practical package for a permanent installation. Its 2024 manufacture and Perkins / Stamford combination offer an alternative to ordering a new high-capacity generating set.
UK delivery and worldwide export are available. Contact FW Power for a quotation, inspection appointment and confirmation of the specification for your project.
Key features
- Heavy-duty industrial construction and acoustic, weather-resistant enclosure
- Perkins V12 engine with turbocharging and water-cooled aftercooling
- Electronic engine governing
- Stamford S6L1D-H41 alternator
- 2500-litre integral diesel fuel tank
- Suitable for automatic mains-failure applications
- Large-capacity output circuit breaker
- Digital generator control and monitoring system
- Battery starting system, engine coolant heater and battery charging system
- Emergency stop and engine / alternator protection
- Suitable for permanent standby or prime-power installations
Applications
Suitable applications include data centres, manufacturing facilities, hospitals and healthcare, distribution centres, warehouses, telecommunications, commercial buildings, industrial facilities, construction projects, critical infrastructure, emergency standby power, large UPS-supported installations and export power projects. Final selection depends on the site load and operating duty.
Inspection and testing
Inspection is available by prior appointment. A full-load bank test and witness testing can be arranged on request.
FW Power can also provide pre-delivery inspection, servicing, commissioning, installation, ATS and control systems, fuel systems, generator maintenance contracts, UK delivery and worldwide export support. Contact the team to agree the scope and quotation.
Delivery and export
FW Power can arrange delivery throughout the United Kingdom and assist with worldwide export and shipping. Contact the team regarding export documentation, port delivery, loading, container or RoRo shipping, customs documentation, commercial invoices and Bills of Lading.
Tell us your delivery location, access and offloading facilities so we can quote the transport requirements. Shipping arrangements and equipment suitability are confirmed for each project.
Enquire about FWC003
Adam Lavin · Sales Director
+44 7424 980523 · WhatsApp · Adam@fwpower.co.uk
Subject to prior sale.
Quote reference FWC003 when enquiring about this generator.
Specifications
| Manufacturer | Shenton Group |
|---|---|
| Model | PHG1500Pe |
| Availability | Available; subject to prior sale |
| Condition | Used |
| Price | POA |
| kVA | 1360 prime / 1500 standby |
| Prime output | 1360 kVA / 1088 kW |
| Standby output | 1500 kVA / 1200 kW |
| Year | 2024 |
| Hours Run | Test Hours Only |
| Engine | Perkins 4012-46TWG3A V12 |
| Alternator | Stamford S6L1D-H41 |
| Voltage | 400 / 230 V |
| Frequency | 50 Hz |
| Phase | 3 |
| Power factor | 0.8 |
| Speed | 1500 rpm |
| Configuration | Acoustic / weatherproof enclosure |
| Fuel | Diesel |
| Fuel tank capacity | 2500 litres |
| Dry weight | Approximately 14,500 kg |
| Dimensions (L × W × H) | Approximately 7000 × 2273 × 2601 mm |
| Noise level | Approximately 70 dB(A) at 7 metres |
| Generator serial number | PM24334-19328 |
Ratings, hours and condition are confirmed in your quotation. Ask our team for any specification that is not listed.
Perkins engine specifications
| Manufacturer | Perkins |
|---|---|
| Model | 4012-46TWG3A |
| Type | 4-stroke diesel |
| Configuration | V12 |
| Displacement | Approximately 45.5 litres |
| Bore × stroke | 160 × 190 mm |
| Aspiration | Turbocharged |
| Aftercooling | Water-cooled / JWAC |
| Cooling system | Water cooled |
| Fuel system | Direct injection |
| Governor | Electronic |
| Rated speed | 1500 rpm |
| Starting system | 24 V DC |
| Engine identification | U20028K |
| Rated mechanical output | Approximately 1263 kWm |
Stamford alternator specifications
| Manufacturer | STAMFORD / Cummins Generator Technologies |
|---|---|
| Model | S6L1D-H41 |
| Serial number | X24G304721 |
| Continuous alternator rating | 1400 kVA / 1120 kW |
| Voltage | 400 V |
| Frequency | 50 Hz |
| Speed | 1500 rpm |
| Phase | 3 |
| Connection | Star |
| Power factor | 0.80 |
| Rated current | 2020.8 A |
| Winding | 312 |
| Insulation class | Class H |
| Ingress protection | IP23 |
| Temperature rise | 125 K |
| Rated ambient temperature | 40°C |
| Altitude rating | 1000 metres |
| Alternator weight | Approximately 2836 kg |
This listing uses the supplied specification for the fitted Stamford S6L1D-H41 alternator. Alternator continuous rating and complete generating-set duty ratings are shown separately.
Fuel consumption and tank capacity
| 50% prime load | Approximately 149 litres/hour |
|---|---|
| 75% prime load | Approximately 212 litres/hour |
| 100% prime load | Approximately 281 litres/hour |
| Integral tank capacity | 2500 litres |
| Operation at 75% load | Approximately 11.5 hours, subject to operating conditions |
Approximate manufacturer figures supplied for this listing. Actual consumption and runtime depend on load, operating conditions and usable fuel capacity.
Electrical output
| Prime power | 1360 kVA / 1088 kW |
|---|---|
| Standby power | 1500 kVA / 1200 kW |
| Approximate prime current at 400 V | 1963 A |
| Approximate standby current at 400 V | 2165 A |
Prime power is intended for extended operation with varying loads. Standby power is intended for emergency operation during mains failure. Confirm the required duty and site loading with FW Power.
Delivery & options
UK delivery or collection
Tell us your postcode and whether you can offload the generator. We can quote for suitable transport, including Hiab delivery where required, or arrange collection from our Cheshire yard.
Worldwide export
Delivery is quoted separately. Send the final destination and your handling requirements so we can discuss transport and shipping.
Installation & support
Ask about installation and commissioning, automatic transfer switches and ongoing servicing for your application.